Get Support

123-456-789-10

TR | EN | RU | ES | AR

Membrane APP Modified Bituminous Membranes

Basic Information
• They can be adhered to Emülzer C or Emilkote primed surfaces by torch application. First coat membranes must be adhered solely at overlaps, and second coat membranes must be adhered to the first coat membrane as well as the overlaps. Note that the surfaces are not primed in packaging applications.
• At seams they should overlap 10 cm horizontally, and 15 cm vertically. For ease of use, overlap points are marked on Emülzer membranes.
• Bituminous membranes must be applied at least in two coats and zigzagging (must be 50 cm horizontally and 5 meters vertically).
EM 200C - EM 300C Polimer Bituminous Membranes
Description
2-3 mm thick bituminous membranes reinforced with fiber glass. Both
sides are covered with PE film.
Usage Areas
They are used as the first coat in shingle, slated or aluminum foiled
membrane applications.
EM 300P - EM 400P Polimer Bituminous Membranes
3-4 mm thick bituminous membranes reinforced with polyester felt. Both sides are covered with PE film.
Usage Areas
Used in 2 coats in foundation packaging insulation, and as the first coat in shingle, slated or aluminum foiled membrane applications. Advantages
Thanks to polyester felt reinforcement, they offer high tensile strength as well as extension strength.
EM 300 PAR Slate Coated Bituminous Membranes
3mm thick, red or green slate stone coated membranes reinforced with polyester felt.
Usage Areas
Used as the top coat membrane on metal surfaces with no UV exposure and foot traffic.
Advantages
As a light material, there is no load problem for the roof. Very decorative with its natural stone coating.

TEKNİK ÖZELLİKLER BİRİM STANDART 300P 400P
Taşıyıcı gr/m2 TS 11758-1 Polyester Polyester
Yüksek Sıcaklığa Maruz Bırakarak Yapay Yaşlandırma kPa TS EN 1296 Type A 2 kPa; Type T 60 kPa Type A 2 kPa; Type T 60 kPa
Yırtılmaya Karşı Direnç (En/Boy) N TS EN 12310-1 35/75 N (+-%50) 50/100 N (+-%50)
Statik Yüklere Karşı Direnç kg TS EN 12730 min.5 kg min.5 kg
Çekme Mukavemeti (Boyuna) N/5cm TS EN 12311-1 400 N/5 cm (+-%50) 600 N/5 cm (+-%50)
Kopma Uzaması (Boyuna) % TS EN 12311-1 % 30 (+-%50) % 30 (+-%50)
Darbeye Karşı Direnç mm TS EN 12691 method A min.300 mm. min.300 mm.
Çekme Mukavemeti (Enine) N/5cm TS EN 12311-1 300 N/5 cm (+-%50) 400 N/5 cm (+-%50)
Kopma Uzaması (Enine) % TS EN 12311-1 % 30 (+-%50) % 30 (+-%50)
Ek Yeri Dayanımı N/5cm TS EN 12317-1 300N/5cm (+-%50) 400N/5cm (+-%50)
Düşük Sıcaklıklarda Esneklik 0C TS EN 1109 max. - 5 º C max. - 5 º C
Yangına Tepki   TS EN ISO 11925-2 Class E Class E
Kalınlık mm TS EN 1849-1 3 mm (+-0,5 mm) 4 mm (+-0,5 mm)
Düzlükten Sapma mm TS EN 1848-1 Max. 20 mm for 10 meter Max. 20 mm for 10 meter
Genişlik m TS EN 1848-1 min. 1 meter min. 1 meter
Uzunluk m TS EN 1848-1 min. 10 meter min. 10 meter
Birim Alan Kütlesi kg/m2 TS EN 1849-1 3,9(+-1) kg/m2 4,9(+-1) kg/m2

 

Türk Malı
Türk Ak
İzoder
Suder
Szutest